OFTEN KILLING PORT on cmd when rerunning project - what's causing this?

$
0
0
Often when making a change and re-running  our Mendix project locally, we will wait for the modeller to deploy (10 minutes) and almost every time we do a  rerun (this does not happen on the first run when opening  and then running the project) we are receiving this popup error below with some cryptic messaging. Error Message Details: Mendix.Modeler.M2EEConnector.M2EEException: Request <{"action":"get_log_settings","params":{"subscriber":"TcpJsonLogSubscriber-a48c546b-3dc5-4f50-8d7d-591e641b0fce"}}> failed:  ---> System.Net.WebException: The request was aborted: The operation has timed out.    at System.Net.HttpWebRequest.GetResponse()    at Mendix.Modeler.M2EEConnector.M2EERequest.DoHttpRequest(String json, Int32 timeout) in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.M2EEConnector\M2EERequest.cs:line 173    --- End of inner exception stack trace ---    at Mendix.Modeler.M2EEConnector.M2EERequest.DoHttpRequest(String json, Int32 timeout) in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.M2EEConnector\M2EERequest.cs:line 186    at Mendix.Modeler.M2EEConnector.M2EERequest.Execute(Int32 timeout) in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.M2EEConnector\M2EERequest.cs:line 69    at Mendix.Modeler.M2EEConnector.M2EEClient.GetLogLevels(String subscriberName) in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.M2EEConnector\M2EEClient.cs:line 90    at Mendix.Modeler.M2EEConnector.RuntimeController.Stop() in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.M2EEConnector\RuntimeController.cs:line 152    at Mendix.Modeler.UIFramework.Progress.ProcessRunner.RunStep(Step step) in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.UIFramework\Progress\ProcessRunner.cs:line 81    at Mendix.Modeler.UIFramework.Progress.ProcessRunner.OnDoWork(Object sender, DoWorkEventArgs e) in C:\jenkins-ci\workspace\AppStudio3.0-Build@2\modeler\Mendix.Modeler.UIFramework\Progress\ProcessRunner.cs:line 61    at System.ComponentModel.BackgroundWorker.OnDoWork(DoWorkEventArgs e)    at System.ComponentModel.BackgroundWorker.WorkerThreadStart(Object argument) I then have to keep killing the port in the windows cmdline; in order to be able to rerun the application again.   does anybody else experience/know the cause of this error/issue?        

Viewing all articles
Browse latest Browse all 83469

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>